HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
267HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
83050100 An unsupported message type or terminal request was received by the
CFMENU
utility code from the CLI.
01
84010100 An unsupported message type or terminal request was received by the
CLONE
virtual terminal code from the CLI.
01
85010100
HSUTIL
tried to release a facility that was not reserved by
HSUTIL
.01
85020100
HSUTIL
tried to change the unit state from Maintenance to Normal mode
but was rejected because of insufficient resources.
01
85030100
HSUTIL
tried to change the USB unit state from Maintenance to Normal
mode, but
HSUTIL
never received notification of a successful state
change.
01
85040100
HSUTIL
tried to switch the unit state from Maintenance to Normal mode
but was not successful.
01
86000020 Controller was forced to restart in order for new code load or patch to
take effect.
00
86010010 The controller code load function is about to update the program card.
This requires controller activity to cease. This code is used to inform the
“other controller” that “this controller” has stopped responding to
inter-controller communications during card update. An automatic
restart of the controller at the end of the program card update causes
normal controller activity to resume.
00
86020011 The EMU firmware returned a bad status after directed to prepare for a
code load:
Last failure parameter [0] contains the value of the bad status.
00
Table 56: Last Failure Codes and Repair Action Codes (Sheet 54 of 55)
Last
Failure
Code
Description
Repair
Action
Code