HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
261HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
201B0100
201C0100
Insufficient resources to get memory to lock CLI.
Changes to unlock.
01
20200100 CLI$ALLOCATE_STRUCT( ) could not obtain memory for a new
NVFOC_RW_REMOTE_NVMEM structure.
01
20220020 This controller requested this subsystem to power off. 00
20230000
A restart of both controllers is required after exiting Multibus Failover
mode.
00
20260000 With “SET FAILOVER COPY=OTHER,” the controller to which the
configuration is copied is automatically restarted by this bugcheck.
00
20640000
20650000
Nindy was turned on.
Changes to off.
00
20692010 To enter Dual-redundant mode, both controllers must be of the same
type.
20
206A0000
206B0010
Controller restart forced by DEBUG CRASH REBOOT command.
Changes to DEBUG CRASH NOREBOOT.
00
206C0020 Controller was forced to restart in order for new controller code image to
take effect.
00
206D0000 Controller code load was not completed because the controller could not
rundown all units.
00
206E0000 A restart of both controllers is required after entering Multiple-bus
Failover and the last Failover mode of the source controller was
Transparent, or after entering Transparent Failover and the last Failover
mode of the source controller was Multipl-bus.
00
43000100 Encountered an unexpected structure type on HP_WORK_Q.01
43030100 Unable to allocate the necessary number of large sense data buckets in
HPP_INIT( ).
01
43100100 Encountered a NULL completion routine pointer in a DD. 01
43130100 Could not allocate a large sense bucket. 01
43160100 A sense data bucket of unknown type (neither large nor small) was
passed to DEALLOCATE_SDB( ).
01