HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
244 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03790188 A PCI bus fault was detected by a device port:
Last failure parameter [0] contains the PCB PORT_PTR value.
Last failure parameter [1] contains the PCB copy of the device port TEMP
register.
Last failure parameter [2] contains the PCB copy of the device port DBC
register.
Last failure parameter [3] contains the PCB copy of the device port
DNAD register.
Last failure parameter [4] contains the PCB copy of the device port DSP
register.
Last failure parameter [5] contains the PCB copy of the device port DSPS
register.
Last failure parameter [6] contains the PCB copies of the device port
SSTAT2/SSTAT1/SSTAT0/DSTAT registers.
Last failure parameter [7] contains the PCB copies of the device port
LCRC/RESERVED/ISTAT/DFIFO registers.
01
03820100 Failed request for mapping table memory allocation. 01
03830100 Failed request for SYM53C875 PCI block memory allocation. 01
03850101 DS_ALLOC_MEM called with invalid memory type:
Last failure parameter [0] contains the invalid memory type.
01
03860100 DS_ALLOC_MEM was unable to get requested memory allocated; NULL
pointer returned.
01
038C0100 Insufficient memory available for completion of DWD array allocation. 01
03980100 Failed to allocate expandable EMU static work structures. 01
03990100 Failed to allocate expandable EMU work entry. 01
039A0100 Failed to allocate expandable EMU FOC work entry. 01
039B0100 EMU request work queue corrupted. 01
039C0100 EMU response work queue corrupted. 01
039D0100 EMU work queue corrupted. 01
039E0100 EMU FOC request work queue corrupted. 01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 31 of 55)
Last
Failure
Code
Description
Repair
Action
Code