HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
225HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02570102 An invalid status was returned from VA$XFER( ) during an operation:
Last failure parameter [0] contains the DD address.
Last failure parameter [1] contains the invalid status.
01
025A0102 An invalid status was returned from CACHE$LOOKUP_LOCK( ):
Last failure parameter [0] contains the DD address.
Last failure parameter [1] contains the invalid status.
01
02690102 An invalid status was returned from CACHE$OFFER_WRITE_DATA( ):
Last failure parameter [0] contains the DD address.
Last failure parameter [1] contains the invalid status.
01
027B0102 An invalid status was returned from VA$XFER( ) in a complex
ACCESS operation:
Last failure parameter [0] contains the DD address.
Last failure parameter [1] contains the invalid status.
01
027D0100 Unable to allocate memory for a Failover Control Block. 01
027E0100 Unable to allocate memory for a Failover Control Block. 01
027F0100 Unable to allocate memory for a Failover Control Block. 01
02800100 Unable to allocate memory for a Failover Control Block. 01
02840100 Unable to allocate memory for the XNode array. 01
02860100 Unable to allocate memory for the Fault Management Event Information
Packet used by the Cache Manager in generating error logs to the host.
01
02880100 Invalid Failover control (FOC) message in CMFOC_SND_CMD.01
028A0100
028B0100
Invalid return status from DIAG$CACHE_MEMORY_TEST.01
028C0100 Invalid error status given to CACHE_FAIL.01
028E0100 Invalid Device Correlation Array (DCA) state detected in
INIT_CRASHOVER.
01
02910100 Invalid metadata combination detected in BUILD_RAID_NODE.01
02920100 Unable to handle that many bad dirty pages (exceeded
MAX_BAD_DIRTY). Cache memory is bad.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 12 of 55)
Last
Failure
Code
Description
Repair
Action
Code