HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
219HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
018F2087 A NMI interrupt was generated with an indication that a controller
system problem occurred:
Last failure parameter [0] contains the value of read diagnostic register
0.
Last failure parameter [1] contains the value of read diagnostic register
1.
Last failure parameter [2] contains PCI status. Bits 31::24 hold PCI FX
engine (PCFX) PCI Status Command Register (PSCR) status and bits
15::08 hold PLX (bridge chip) PSCR status.
Last failure parameter [3] contains the PCFX PCI Data or Address Line
(PDAL) control and status register.
Last failure parameter [4] contains the Intel bus (IBUS) address of error
register.
Last failure parameter [5] contains the previous PDAL address of error
register.
Last failure parameter [6] contains the current PDAL address of error
register.
20
01902086 The PCI bus on the controller does not allow a master to initiate a
transfer. Unable to provide further diagnosis of the problem:
Last failure parameter [0] contains the value of read diagnostic register
0.
Last failure parameter [1] contains the value of read diagnostic register
1.
Last failure parameter [2] contains the value of read diagnostic register
2.
Last failure parameter [3] contains the value of write diagnostic register
0.
Last failure parameter [4] contains the value of write diagnostic register
1.
Last failure parameter [5] contains the IBUS address of error register.
20
Table 56: Last Failure Codes and Repair Action Codes (Sheet 6 of 55)
Last
Failure
Code
Description
Repair
Action
Code