HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
217HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
01170108 The Intel i960 processor reported a machine fault parity error while an
NMI was being processed:
Last failure parameter [0] contains the reserved value.
Last failure parameter [1] contains the access type value.
Last failure parameter [2] contains the access address value.
Last failure parameter [3] contains the number of faults value.
Last failure parameter [4] contains the process controls register (PC)
value.
Last failure parameter [5] contains the arithmetic controls register (AC)
value.
Last failure parameter [6] contains the fault type and subtype values.
Last failure parameter [7] contains the RIP value.
01
01180105 A machine fault (parity error) occurred during EXEC$BUGCHECK
processing:
Last failure parameter [0] contains the executive flags value.
Last failure parameter [1] contains the RIP from the machine fault stack.
Last failure parameter [2] contains the read diagnostic register 0 value.
Last failure parameter [3] contains the FX Chip CSR value.
Last failure parameter [4] contains the SIP LFC value.
01
011B0108 The Intel i960 processor reported a machine fault nonparity error:
Last failure parameter [0] contains the Fault Data (2) value.
Last failure parameter [1] contains the Fault Data (1) value.
Last failure parameter [2] contains the Fault Data (0) value.
Last failure parameter [3] contains the Number of Faults value.
Last failure parameter [4] contains the PC value.
Last failure parameter [5] contains the AC value.
Last failure parameter [6] contains the Fault Flags, Type and Subtype
values.
Last failure parameter [7] contains the RIP value (actual).
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 4 of 55)
Last
Failure
Code
Description
Repair
Action
Code