HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
204 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03F70401 The shelf, indicated by the Associated Port field, is
reporting a problem. This condition could mean one
or both of the following:
If the shelf uses dual power supplies, one power
supply failed.
One of the shelf cooling fans failed.
In this instance, the Associated Target, Associated
ASC, and Associated ASCQ fields are undefined.
41 04
03F80701 The EMU detected one or more bad power supplies.
In this instance, the Associated Target, Associated
ASC, and Associated ASCQ fields are undefined.
41 07
03F90601 The EMU detected one or more bad fans. In this
instance, the Associated Target, Associated ASC, and
Associated ASCQ fields are undefined.
41 06
03FA0D01 The EMU detected an elevated temperature condition.
In this instance, the Associated Target, Associated
ASC, and Associated ASCQ fields are undefined.
41 0D
03FB0E01 The EMU detected an external air sense fault. In this
instance, the Associated Target, Associated ASC, and
Associated ASCQ fields are undefined.
41 0E
03FC0F01 The EMU-detected power supply fault is now fixed. In
this instance, the Associated Target, Associated ASC,
and Associated ASCQ fields are undefined.
41 0F
03FD0F01 The EMU-detected bad-fan fault is now fixed. In this
instance, the Associated Target, Associated ASC, and
Associated ASCQ fields are undefined.
41 0F
03FE0F01 The EMU-detected elevated temperature fault is now
fixed. In this instance, the Associated Target,
Associated ASC, and Associated ASCQ fields are
undefined.
41 0F
Table 53: Instance Codes and Repair Action Codes (Sheet 24 of 30)
Instance
Code
Description Template
Repair
Action