HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Instance Codes
198 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03CA4002 A byte transfer timeout occurred during operation to a
device that is unknown to the controller. In this
instance, the associated ASC and associated ASCQ
fields are undefined.
41 40
03CB0101 A miscellaneous SCSI port driver coding error was
detected during operation to a device that is unknown
to the controller. In this instance, the associated ASC
and associated ASCQ fields are undefined.
41 01
03CC0101 An error code was reported that was unknown to the
fault management software. In this instance, the
associated ASC and associated ASCQ fields are
undefined.
41 01
03CD2002 The device port SCSI chip reported a gross error
during operation to a device that is unknown to the
controller. In this instance, the associated ASC and
associated ASCQ fields are undefined.
41 20
03CE2002 Non-SCSI bus parity error during operation to a
device that is unknown to the controller. In this
instance, the associated ASC and associated ASCQ
fields are undefined.
41 20
03CF0101 A source driver programming error was encountered
during operation to a device that is unknown to the
controller. In this instance, the associated ASC and
associated ASCQ fields are undefined.
41 01
03D04002 A failure occurred while attempting a SCSI TEST
UNIT READY or READ CAPACITY command to a
device. The device type is unknown to the controller.
In this instance, the associated ASC and associated
ASCQ fields are undefined (see the “Device Discovery
Error report” section that starts on page 53).
41 40
Table 53: Instance Codes and Repair Action Codes (Sheet 18 of 30)
Instance
Code
Description Template
Repair
Action
Code