HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
185HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02402301 The cache backup battery covering the mirror cache
was declared bad. Either the battery failed testing
performed by the cache diagnostics during system
startup or the battery was low (insufficiently charged)
for longer than the expected duration. The Memory
Address field contains the starting physical address of
the Cache B1 memory.
12 23
02412401 Mirrored cache writes have been disabled. Either the
primary or the mirror cache is bad, or the data is
invalid and is not used. In this instance, the Memory
Address, Byte Count, FX Chip Register, Memory
Controller Register, and Diagnostic Register fields are
undefined.
14 24
02422464 Cache failover attempt failed because the other cache
was illegally configured with DIMMs. In this instance,
the Memory Address, Byte Count, FX Chip Register,
Memory Controller Register, and Diagnostic Register
fields are undefined.
14 24
02492401 The write cache module, that is the mirror for the
primary cache, is unexpectedly not present (missing).
A cache is expected to be configured and the cache
may contain dirty write cached data. In this instance,
the Memory Address, Byte Count, FX Chip Register,
Memory Controller Register, and Diagnostic Register
fields are undefined.
14 24
024A2401 Mirroring is enabled and the primary write cache
module is unexpectedly not present (missing). A cache
is expected to be configured and the cache may
contain dirty write cached data. In this instance, the
Memory Address, Byte Count, FX Chip Register,
Memory Controller Register, and Diagnostic Register
fields are undefined.
14 24