HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
184 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
022C0064 The device, specified in the Device Locator field, has
transitioned from Copying or Normalizing state to the
Normal state.
51 00
022E0064 The device, specified in the Device Locator field, was
converted to a mirrorset associated with the logical
unit.
51 00
022F0064 The mirrored device specified in the Device Locator
field was converted to a single device associated with
the logical unit.
51 00
02383A01 The Cache B0 memory controller that resides on the
other cache module failed testing performed by the
cache diagnostics. This is the mirrored cache memory
controller. The Memory Address field contains the
starting physical address of the Cache B0 memory.
14 3A
02392201 Both the Cache B0 memory controller and Cache B1
memory controller, that reside on the other cache
module, failed testing performed by the cache
diagnostics. Data cannot be accessed in the primary
cache or the mirror cache. The Memory Address field
contains the starting physical address of the Cache
A0 memory.
14 22
023E2401 Metadata residing in the controller and on the two
cache modules disagree on the mirror node. In this
instance, the Memory Address, Byte Count, FX Chip
Register, Memory Controller Register, and Diagnostic
Register fields are undefined.
14 24
023F2301 The cache backup battery covering the mirror cache is
insufficiently charged. The Memory Address field
contains the starting physical address of the Cache B1
memory.
12 23
Table 53: Instance Codes and Repair Action Codes (Sheet 4 of 30)
Instance
Code
Description Template
Repair
Action
Code