HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Instance Codes
181HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Table 53 contains the numerous Instance Codes, in ascending order, that might be
issued by the controller fault management software.
Table 53: Instance Codes and Repair Action Codes (Sheet 1 of 30)
Instance
Code
Description Template
Repair
Action
Code
01010302 An unrecoverable hardware-detected fault occurred. 01 03
0102030A An unrecoverable software inconsistency was
detected or an intentional restart or shutdown of
controller operation was requested.
01 03
01032002 Nonvolatile parameter memory component Error
Detection Code (EDC) check failed; content of the
component reset to default settings.
11 20
02020064 Disk bad block replacement attempt completed for a
write within the user data area of the disk. Note that
due to the way bad block replacement is performed
on SCSI disk drives, information on the actual
replacement blocks is not available to the controller
and is, therefore, not included in the event report.
51 00
02032001 Journal Static Random Access Memory (SRAM)
backup battery failure detected during system restart.
The Memory Address field contains the starting
physical address of the Journal SRAM.
12 20
02042001 Journal Static Random Access Memory (SRAM)
backup battery failure detected during periodic
recheck. The Memory Address field contains the
starting physical address of the Journal SRAM.
02052301 A processor interrupt was generated by the Cache A0
memory controller with an indication that the cache
backup battery has failed or is low (needs charging).
The Memory Address field contains the starting
physical address of the Cache A0 memory.
12 23
02072201 The Cache AO memory controller failed testing
performed by the cache diagnostics. The Memory
Address field contains the starting physical address of
the Cache A0 memory.
14 22
02082201 Changes to Cache A1. 14 22