HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
103HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Screen header
The screen header is the first line of data on every display screen. The header
shows information about the overall performance of the storage subsystem and is
further divided into the following four subsections:
■ Controller ID data
■ Subsystem performance data
■ Controller uptime data
■ Current date and time
The controller ID data appears as follows:
HSG80 S/N: xxxxxxxxxxxx SW: xxxxxxx HW: xx-xx
where:
■ HSG80 (or HSG60)—Represents the controller model name and number.
■ S/N—Depicts an alphanumeric serial number.
■ SW—Depicts a software version number.
■ HW—Depicts a hardware revision number.
The subsystem performance data appears as follows:
xxx.x% Idle xxxxxx KB/S xxxxx RQ/S
where:
■ xxx.x% Idle—Displays the controller policy processor uptime.
■ KB/s—Displays cumulative data transfer rate in kilobytes per second.
■ RQ/S—Displays cumulative unit request rate in requests per second.
The controller uptime data shows the uptime of the controller in days, hours and
minutes in the following format:
Up: days hh:mm:ss