HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
200 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
To enable SCSI fairness, enter:
AP_TOP> SET THIS SCSI_FAIRNESS=ENABLE
Controller:
HSG80 ZG94715677 Software V88P-1, Hardware E10
NODE_ID = 5000-1FE1-0008-06D0
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG12345678
In dual-redundant configuration
Device Port SCSI address 6
Time: 19-JAN-2004 17:08:27
Command Console LUN is lun 0 (NOIDENTIFIER)
Host Connection Table is NOT locked
Smart Error Eject Disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0008-06D1
PORT_1_TOPOLOGY = FABRIC (fabric up)
Address = 031200
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0008-06D2
PORT_2_TOPOLOGY = FABRIC (fabric up)
Address = 031100
REMOTE_COPY = LEFT
Cache:
256 megabyte write cache, version 0022
Cache is GOOD
No unflushed data in cache
CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
Mirrored Cache:
256 megabyte write cache, version 0022
Cache is GOOD
No unflushed data in cache