HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
180 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Parameters
The following parameter is associated with this SET command:
concatset-name
Identifies the name of the concatset to be expanded.
Switches
The following switch supports the SET concatset-name command:
ADD=storage-set-name
Concatenates the storageset specified by storage-set-name to the
concatset.
Examples
To expand the capacity of unit D0 which consists of stripeset Stripe1, by adding
another stripeset (Stripe2), enter:
ADD CONCATSETS C1 STRIPE1
SET C1 ADD=STRIPE2
See Also
ADD CONCATSETS
DELETE concatset-name
SHOW CONCATSETS