HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
229HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02D90100 Bad CLD pointer passed SETWB routine. 01
02DA0100 A fatal logic error occurred while trying to restart a stalled data transfer
stream.
01
02DB0100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory
while populating the disk read PCI XOR engine (PCX) DWD stack.
01
02DC0100 Changes to disk write. 01
02DD0102 The VA state change deadman timer expired, and at least one VSI was
still interlocked.
Last failure parameter [0] contains the NV_INDEX.
Last failure parameter [1] contains the address of the locking routine.
01
02DD0104 The VA state change deadman timer expired, and at least one VSI was
still interlocked.
Last Failure Parameter[0] contains the NV_INDEX.
Last Failure Parameter[1] contains the address of the locking routine.
Last Failure Parameter[2] bit mask of resource waiters.
Last Failure Parameter[3] contains the address of the waiter routine.
02DE0100 An attempt to allocate memory for a NULL PUB failed to get the
memory.
01
02DF0101 License identified in last failure parameter [0] was not forced valid. 01
02E00180 Mirror functionality is broken. 01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 16 of 55)
Last
Failure
Code
Description
Repair
Action
Code