HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
218 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
011C0011 Controller execution stopped through display of solid fault code in OCP
LEDs. Upon receipt of this failure in a last gasp message, the “other
controller” in a dual-redundant configuration inhibits assertion of the kill
line.
Last failure parameter [0] contains the OCP LED solid fault code value.
00
011D0100 Relocated zero (for example, C0000000) entered through call or
branch.
01
018000A0 A power-fail interrupt occurred. 00
018600A0 A processor interrupt was generated with an indication that the “other
controller” in a dual-redundant configuration asserted the kill line to
disable “this controller.
00
018700A0 A processor interrupt was generated with an indication that the (//)
Reset button on the controller module was depressed.
00
018800A0 A processor interrupt was generated with an indication that the program
card was removed.
00
018900A0 A processor interrupt was generated with an indication that the
controller inactivity watchdog timer expired.
00
Table 56: Last Failure Codes and Repair Action Codes (Sheet 5 of 55)
Last
Failure
Code
Description
Repair
Action
Code