HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
187HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
0257000A An attempt to reassign a bad disk block failed. The
contents of the disk block are lost. The Information
field of the device sense data contains the block
number of the first block in error.
51 00
0258000A This command was aborted prior to completion. The
Information field of the device sense data contains the
block number of the first block in error.
51 00
0259000A The write operation failed because the unit is
hardware write-protected. The Information field of the
device sense data contains the block number of the
first block in error.
51 00
025A000A The command failed because the unit became
inoperative prior to command completion. The
Information field of the device sense data contains the
block number of the first block in error.
51 00
025B000A The command failed because the unit became
unknown to the controller prior to command
completion. The Information field of the device sense
data contains the block number of the first block in
error.
51 00
025C000A The command failed because of a unit media format
error. The Information field of the device sense data
contains the block number of the first block in error.
51 00
025D000A The command failed for an unknown reason. The
Information field of the device sense data contains the
block number of the first block in error.
51 00
Table 53: Instance Codes and Repair Action Codes (Sheet 7 of 30)
Instance
Code
Description Template
Repair
Action
Code