HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)
CLI Command Descriptions
202 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Figure 9 shows an example of how to enable the SMART error drive eject setting.
Figure 9: Sample screen display showing how to enable the SMART error drive
eject setting
See Also
RESTART controller
SET MULTIBUS_FAILOVER
SHOW controller
SHUTDOWN controller
SHOW controller
AP_TOP> show this
Controller:
HSG80 ZG02804912 Software V88S-1, Hardware E12
NODE_ID = 5000-1FE1-FF00-0090
ALLOCATION_CLASS = 1
SCSI_VERSION = SCSI-3
Configured for MULTIBUS_FAILOVER with ZG02804288
In dual-redundant configuration
Device Port SCSI address 7
Time: 22-MAY-2004 01:17:47
Command Console LUN is lun 0 (IDENTIFIER = 99)
Host Connection Table is NOT locked
Smart Error Eject Enabled