HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide (EK-G80CL-RA. C01, March 2005)

CLI Command Descriptions
183HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Command Line Interface Reference Guide
Note: If a particular host prefers either the CONNECTION_BASED or
HBA_PORT_ID_BASED reservation style, all the connections to that particular host
must have identical reservation style settings.
The most important advantage of this mechanism is allowing various hosts, with
different reservation style requirements, to be connected to the same HSG60 and
HSG80 controllers in a SAN environment.
UNIT_OFFSET
Establishes the beginning of the range of units that a host connection can
access. It is expressed as a decimal value (and is usually just called offset). It
defines and restricts host connection access to a contiguous group of unit
numbers.
If no value is specified for the UNIT_OFFSET switch, then host connections
have default offsets as follows:
In Transparent Failover mode, connections on port 1 have an offset of 0
and connections on port 2 have an offset of 100.
In Multiple-bus Failover mode, all connections have an offset of 0.
The relationship between LUN number, unit number, and offset is as follows:
LUN = unit-number – offset
Logical unit-number (LUN) = the logical unit-number presented to the
host connection
Unit-number = the number assigned to the unit in the ADD UNITS
command. This is the number by which the unit is known internally to the
controllers.
Example
set !newcon31 operating_system=vms unit_offset=20
See Also
ADD CONNECTIONS
SHOW CONNECTIONS
DELETE connection-name
RENAME