HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
232 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02F54083 The device saved configuration information selected for the restore
process is from an unsupported controller type. Remove the device with
the unsupported information and retry the operation:
Last failure parameter [0] contains the disk port.
Last failure parameter [1] contains the disk target.
Last failure parameter [2] contains the disk LUN.
40
02F60103 An invalid modification to the NO_INTERLOCK VSI flag was attempted:
Last failure parameter [0] contains the NV_INDEX of the config on which
the problem was found.
Last failure parameter [1] contains the modification flag.
Last failure parameter [2] contains the current value of the
NO_INTERLOCK flag.
If the modification flag is 1, then an attempt was being made to set the
NO_INTERLOCK flag, and the NO_INTERLOCK flag was not clear at
the time. If the modification flag is 0, then an attempt was being made to
clear the NO_INTERLOCK flag, and the NO_INTERLOCK flag was not
set (== 1) at the time.
01
02F70100 During power on testing, one or more device ports (SCSI) were found to
be bad. Due to a problem in the SYM53C770 chip, the diagnostic may
occasionally fail the port even though the hardware is OKAY. A power
on should clear up the problem. If the port is actually broken, logic to
detect a loop that repeatedly causes the same bugcheck causes a halt.
01
02F80103 An attempt was made to bring a unit online while the Cache Manager
says that a member CLD was not in the appropriate state:
Last failure parameter [0] contains the NV_INDEX of the config on
which the problem was found.
Last failure parameter [1] contains the map type of that configuration.
Last failure parameter [2] contains the value from CACHE$CHECK_CID
that was not acceptable.
01
02F90100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory
while allocating structures for read ahead caching.
01
02FA0100 A Read Ahead Data Descriptor (RADD) is inconsistent. 01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 19 of 55)
Last
Failure
Code
Description
Repair
Action
Code