HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
216 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
010F0110 All structures contained in the SIP and the Last Failure entries have been
reset to their default settings as a result of certain controller
manufacturing configuration activities. If this event is reported at any
other time, follow the recommended Repair Action associated with this
LFC.
01
01100100 Non-maskable interrupt entered but no Non-maskable interrupt
pending. This is typically caused by an indirect call to address 0.
01
01110106 A bugcheck occurred during EXEC$BUGCHECK processing:
Last failure parameter [0] contains the executive flags value.
Last failure parameter [1] contains the RIP from the bugcheck call stack.
Last failure parameter [2] contains the first SIP last failure parameter
value.
Last failure parameter [3] contains the second SIP last failure parameter
value.
Last failure parameter [4] contains the SIP LFC value.
Last failure parameter [5] contains the EXEC$BUGCHECK call LFC value.
01
01140102 DEBUG, ASSUME, or ASSUME_LE macro executed.
Last failure parameter [0] contains the address of the module name
where the macro is located.
Last failure parameter [1] contains the line number within the module
where the macro is located. The high order byte of this value identifies
the macro type: 0 = DEBUG, 1 = ASSUME, 2 = ASSUME_LE.
01
01150106 A bugcheck occurred before subsystem initialization completed:
Last failure parameter [0] contains the executive flags value.
Last failure parameter [1] contains the RIP from the bugcheck call stack.
Last failure parameter [2] contains the first SIP last failure parameter
value.
Last failure parameter [3] contains the second SIP last failure parameter
value.
Last failure parameter [4] contains the SIP LFC value.
Last failure parameter [5] contains the EXEC$BUGCHECK call LFC
value.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 3 of 55)
Last
Failure
Code
Description
Repair
Action
Code