Instance Codes
182 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02090064 A data compare error was detected during the
execution of a compare modified read or write
command.
51 00
020B2201 Failed read test of a writeback metadata page
residing in cache. Dirty writeback cached data exists
and cannot be flushed to media. The dirty data is lost.
The Memory Address field contains the starting
physical address of the Cache A0 memory.
14 22
020C2201 Cache diagnostics have declared the cache bad
during testing. The Memory Address field contains the
starting physical address of the Cache A0 memory.
14 22
020D2401 The wrong write cache module is configured. The
serial numbers do not match. Either the existing or the
expected cache contains dirty writeback cached data.
In this instance, the Memory Address, Byte Count, FX
Chip Register, Memory Controller Register, and
Diagnostic Register fields are undefined.
14 24
020E2401 The write cache module is missing. A cache is
expected to be configured and contains dirty
writeback cached data. In this instance, the Memory
Address, Byte Count, FX Chip Register, Memory
Controller Register, and Diagnostic Register fields are
undefined.
14 24
02102401 The write cache modules are not configured properly
for a dual-redundant configuration. One of the cache
modules is not the same size to perform cache failover
of dirty writeback cached data. In this instance, the
Memory Address, Byte Count, FX Chip Register,
Memory Controller Register, and Diagnostic Register
fields are undefined.
14 24