HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Instance Codes
180 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Repair action
The Repair Action Code found at byte offset {9}33 indicates the recommended
Repair Action Code assigned to the event. This value is used during
symptom-directed diagnosis procedures to determine what Notification and
Recovery (recommended repair) action to take upon reaching the NR threshold.
For details about recommended Repair Action Codes, see the “ASC, ASCQ,
Repair Action, and Component Identifier Codes” chapter that starts on page 161.
Event number
The event number is located at byte offset {10}34. Combining this number with
the Component ID field value uniquely identifies the reported event.
Component ID
A Component ID is located at byte offset {11}35. This number uniquely identifies
the software component that detected the event. For details about Component ID
numbers, see the “ASC, ASCQ, Repair Action, and Component Identifier Codes”
chapter that starts on page 161.
0A Soft Indicates either an unexpected condition detected by a
controller software component (for example, protocol
violations, host buffer access errors, internal inconsistencies,
uninterpreted device errors, and so forth) or an intentional
restart or shutdown of controller operation.
64 Informational Indicates an event having little or no effect on proper
controller or device operation.
Table 52: Event Notification and Recovery (NR) Threshold Classifications (Continued)
Threshold
Value
Classification Description