HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
124 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
12. Press Enter or Return to accept the hard-error limit default.
13. Press Enter or Return to accept the soft-error limit default.
14. Press Enter or Return to accept the queue depth default.
15. Enter 1 to run the Basic Function test option.
16. Enter Y(es) to enable phase 1, the write test.
17. Enter Y(es) to accept the default percentage of requests that DILX issues as
read requests during phase 2, the random I/O test.
DILX issues the balance as write requests.
18. Enter 0 to select all data patterns that DILX issues for write requests.
19. Enter Y(es) to perform the initial write pass.
20. Enter Y(es) to allow DILX to compare the read and write data.
21. Press Enter or Return to accept the default percentage of reads and writes
that DILX compares.
22. Enter the unit number of the specific unit to be tested (for example, to test
D107, enter the number 107).
23. To test more than one unit, enter the appropriate unit numbers after prompted.
Otherwise, enter N(o) to start the test.
Note: Use the command sequences shown in Table 33 on page 120 to control the
test.
DILX error codes
Table 35 explains the error codes that DILX might display during and after testing.
Table 35:
DILX
Error Codes
Error
Code
Message and Explanation
1 Illegal Data Pattern Number found in data pattern
header.
Explanation:
DILX
read data from the unit and discovered that the data
did not conform to the pattern that
DILX
had previously written.