HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Tru64 UNIX Release Notes (AA-RV1WA-TE, March 2005)

Hardware and Software Support
31HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Tru64
UNIX Release Notes
Notes
You can verify the KGPSA firmware version by using the uerf utility and
looking at the last boot information. You can also find firmware version
information in the
/usr/adm/messages file.
Patch Kit requirements for Tru64 UNIX are as follows:
For Tru64 UNIX V5.1A: Tru64 UNIX V5.1A Patch Kit 6
Table 6: Minimum System Requirements
Component Requirement
Controller
Compatibility
StorageWorks HSG80 Array Controller, ACS V8.8-1 (or a
subsequently patched version of ACS V8.8-1)
Platform Alpha Servers 800, 1000A, 1200, 4000, 4100, 8200, 8400;
DS10, DS10L, DS15, DS20, DS20E, DS20L, DS25, ES40, ES45,
ES47, ES80, GS60, GS60E, GS80, GS140, GS160, GS320,
GS1280
Operating
System
Tru64 UNIX V4.0G and TruClusters V1.6
Tru64 UNIX V5.1A and TruClusters V5.1A
Tru64 UNIX V5.1B and TruClusters V5.1B
Topology Fibre Channel Switched (FC-SW)
SCSI Protocol SCSI-2 (V4.0G)
SCSI-3 (V5.1A and V5.1B)
Failover Mode Transparent (all supported OS versions)
Multi-Bus (V5.X only, built into OS)
Host Mode TRU64_UNIX
Disk Space 500 KB for the program files
Adapter
Compatibility
HP StorageWorks DS-KGPSA-CA 1 Gb, 64-bit/33MHz PCI FC
HBA, HBA driver included with OS, Firmware 3.92a2
HP StorageWorks DS-KGPSA-DA 2 Gb, 64-bit/66MHz PCI FC
HBA, HBA driver included with OS, Firmware 3.92a2
HP StorageWorks DS-KGPSA-EA 2Gb, 64-bit/133MHz PCI-X,
HBA driver included with OS, Firmware 1.81a5
HP StorageWorks DS-A5132-AA 2Gb, 64-bit/133MHz PCI-X,
HBA driver included with OS, Firmware 1.81a5
HP StorageWorks DS-A5134-AA 2Gb, 64-bit/133MHz PCI-X
Dual, HBA driver included with OS, Firmware 1.81a5