HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
80 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Table 14: Disk Device Information (Sheet 1 of 4)
Info Displayed Description
P T Port#, Target#.
The controller only supports sub-LUN 00; therefore, the sub-LUN is
not portrayed. For example, disk40300 would be displayed as
follows:
Example of output:
P T
-----
04 03
Model Device Model ID.
This unique drive model number is assigned by HP and written into
the device firmware by the disk drive vendor. The model ID uniquely
identifies the disk drive model and is the key reference identification
used to determine if the device is on the list of supported disk drives.
Refer to the latest release notes or contact your HP representative for
a list of supported drives.
Note: To retrieve the latest list of devices supported with HSG60 and
HSG80 array controllers, go to the following link:
http://h18006.www 1.hp.com/products/storageworks/softwaredrivers/
acs/
. Select manuals (guides, supplements, addendums, etc) under
self-help resources, and then select HSG60, HSG80, HSJ80, HSZ80
Supported Disk Drive Matrix.
Example of output:
Model
----------
BD0096349A