HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Utilities and Exercisers
70 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Translating event codes
To translate the event codes in the fault management reports for spontaneous
events and failures:
1. Connect a PC or a local terminal to the controller maintenance port.
2. Start FMU with the following command:
RUN FMU
3. Show one or more of the entries with the following command:
DESCRIBE code_type code#
where:
■ code_type is one of those listed in Table 12.
■ code# is the alphanumeric value displayed in the entry.
Table 12: Event Code Types
Item Event Code Type
1. ASC_ASCQ_CODE
1
1. Code types marked with an asterisk (*) require multiple code numbers (see the “Event
Reporting Templates” chapter that starts on page 135 for types codes used in the
various templates; the “ASC, ASCQ, Repair Action, and Component Identifier Codes”
chapter that starts on page 161 for ASC, ASCQ, Repair Action, and Component ID
Codes; the “Instance Codes” chapter that starts on page 177 for Instance Codes; and
the “Last Failure Codes” chapter that starts on page 211 for Last Failure Codes).
2. COMPONENT_CODE
3. CONTROLLER_UNIQUE_ASC_ASCQ_CODE*
4. DEVICE_TYPE_CODE
5. EVENT _THRESHOLD_CODE
6. INSTANCE_CODE
7. LAST_FAILURE_CODE
8. REPAIR_ACTION_CODE
9. RESTART_TYPE
10. SCSI_COMMAND_OPERATION_CODE*
11. SENSE_DATA_QUALIFIERS*
12. SENSE_KEY_CODE
13. TEMPLATE_CODE