HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
258 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
12100310 An image upgrade that updated the cache metadata version failed
because the cache module held dirty data. This was likely caused by
deviating from the required upgrade procedure (by not properly
verifying the integrity of the system prior to the image swap or by
swapping hardware components as part of the procedure). The dirty
data was permanently cleared from the cache. Restart “this controller”
with the pre-upgrade image. If either the SHOW THIS_CONTROLLER
INVALID_CACHE or SHOW UNIT lost data conditions are found, they
must be cleared.
03
12110310 An image upgrade that updated the cache metadata version failed
because the cache module held dirty data. This was likely caused by
deviating from the required upgrade procedure (by not properly
verifying the integrity of the system prior to the image swap or by
swapping hardware components as part of the procedure). The dirty
data was permanently cleared from the cache. Restart “this controller”
with the pre-upgrade image. If either the SHOW THIS_CONTROLLER
INVALID_CACHE or SHOW UNIT lost data conditions are found, they
must be cleared.
03
12120108 The internal consistency checks have determined that the requested
transfer is invalid. The parameters contain transfer specific flags and
values intended for use by the software developers:
Last failure parameter[0] contains the DD address.
Last failure parameter[1] contains the DD LBN.
Last failure parameter[2] contains the DD DBD count.
Last failure parameter[3] contains the DD VA flags.
Last failure parameter[4] contains the HTB VA flags.
Last failure parameter[5] contains the HTB LBA.
Last failure parameter[6] contains the HTB block count.
Last failure parameter[7] contains the USB unit number or the HTB
OpCode.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 45 of 55)
Last
Failure
Code
Description
Repair
Action
Code