HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
239HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03390108 An unknown interrupt code was found in a device port DSPS register:
Last failure parameter [0] contains the PCB PORT_PTR value.
Last failure parameter [1] contains the PCB copy of the device port TEMP
register.
Last failure parameter [2] contains the PCB copy of the device port DBC
register.
Last failure parameter [3] contains the PCB copy of the device port
DNAD register.
Last failure parameter [4] contains the PCB copy of the device port DSP
register.
Last failure parameter [5] contains the PCB copy of the device port DSPS
register.
Last failure parameter [6] contains the PCB copies of the device port
SSTAT2/SSTAT1/SSTAT0/DSTAT registers.
Last failure parameter [7] contains the PCB copies of the device port
LCRC/RESERVED/ISTAT/DFIFO registers.
01
033C0101 An invalid code was seen by the error recovery thread in the
ER_FUNCT_STEP field of the PCB:
Last failure parameter [0] contains the PCB ER_FUNCT_STEP code.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 26 of 55)
Last
Failure
Code
Description
Repair
Action
Code