HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
230 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02E11016 After attempting to restore saved configuration information, data for two
unrelated controllers was found. The restore code is unable to determine
which disk contains the correct information. The port, target, and LUN
information for the two disks is contained in the parameter list. Remove
the disk containing the incorrect information, reboot the controller, and
issue the SET THIS_CONTROLLER INITIAL_CONFIGURATION
command. After the controller restarts, the proper configuration is
loaded:
Last failure parameter [0] contains the first disk port.
Last failure parameter [1] contains the first disk target.
Last failure parameter [2] contains the first disk LUN.
Last failure parameter [3] contains the second disk port.
Last failure parameter [4] contains the second disk target.
Last failure parameter [5] contains the second disk LUN.
10
02E20100 An attempt to allocate a VA_CS_WORK item from the
S_VA_FREE_CS_WORK_QUEUE failed.
01
02E30100 An attempt to allocate a free VA Request (VAR) failed. 01
02E40100 An attempt to allocate a free VAR failed. 01
02E50100 An attempt to allocate a free VAR failed. 01
02E60100 An attempt to allocate a free VAR failed. 01
02E70100 An attempt to allocate a free VAR failed. 01
02E80100 An attempt to allocate a free VAR failed. 01
02E90100 An attempt to allocate a free VAR failed. 01
02EA0100 An attempt to allocate a free VAR failed. 01
02EB0100 An attempt to allocate a free metadata WARP failed. 01
02EC0101 An online request was received for a unit while both controllers had dirty
data for the unit. The crash allows the surviving controller to copy over all
of the dirty data.
Last failure parameter [0] contains the NV_INDEX of the unit.
01
02ED0100 On an attempt to allocate a Buffer Descriptor Block (BDB), that is not
allowed to fail, no freeable BDB was found.
01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 17 of 55)
Last
Failure
Code
Description
Repair
Action
Code