HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Last Failure Codes
226 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02930100 There was no free or freeable buffer to convert bad metadata or to
borrow a buffer during failover of bad dirty data.
01
02940100 A free device correlation array entry could not be found during
writeback cache failover.
01
02950100 Invalid DCA state detected in START_CRASHOVER. 01
02960100 Invalid DCA state detected in START_FAILOVER. 01
02965E0A A bad block was detected on the mirrorset metadata region, and the
requested addition of a new member to the mirrorset could not be
completed.
5E
02970100 Invalid DCA state detected in INIT_FAILOVER. 01
02990100 A free RAID correlation array entry could not be found during writeback
cache failover.
01
029A0100 Invalid cache buffer metadata detected while scanning the buffer
metadata array. Found a page containing dirty data but the
corresponding device correlation array entry does exist.
01
029D0100 Invalid metadata combination detected in BUILD_BAD_RAID_NODE. 01
029F0100 The Cache Manager software has insufficient resources to handle a
buffer request pending.
01
02A00100 Value-added (VA) Change state is trying to change device affinity and
the cache has data for this device.
01
02A10100 Pubs not one when transportable. 01
02A20100 Pubs not one when transportable. 01
02A30100 No available data buffers. If the cache module exists, then this is true
after testing the whole cache. Otherwise, no buffers are allocated from
buffer memory on the controller module.
01
02A40100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory
after allocating VA Transfer Descriptors (VAXDs).
01
02A50100 Changes to DILPs occurred. 01
02A60100 A call to EXEC$ALLOCATE_MEM_ZEROED failed to return memory after
allocating Change State Work Items.
01
02A70100 Changes to VA Request Items. 01
Table 56: Last Failure Codes and Repair Action Codes (Sheet 13 of 55)
Last
Failure
Code
Description
Repair
Action
Code