HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
213HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Last Failure Code format
The format of an LFC is shown in Table 54.
Note: Do not confuse the LFC with that of an Instance Code (see the “Instance Codes
chapter that starts on page 177). Both codes are similar in format, but they convey
different information.
Parameter Count
The Parameter Count is located at byte offset 104, bits 0–3 and indicates the
number of last failure parameters containing supplemental information supplied.
Restart Code
Located at byte offset 104, bits 4–6, the Restart Code describes the actions taken
to restart the controller after the unrecoverable condition was detected. See
Table 55 for available Restart Codes.
Table 54: Last Failure Code Format
offset
bit
7 6 5 4 3 2 1 0
104 HW Restart Code Parameter Count
105 Repair Action
106 Error Number
107 Component ID
Table 55: Controller Restart Codes
Restart Code Description
0 Full software restart.
1No restart.
2 Automatic hardware restart.