HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
209HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
0E1E8C01 The asynchronous merge was terminated due to a
read failure on the initiator unit.
90 8C
0E1F8B01 The asynchronous merge was terminated due to a
write failure on the target unit.
90 8B
0E210064 The logical unit specified by the Target WWLID field
has transitioned from the Normal state to the Write
History Logging state due to a remote connection
event (the target controllers are no longer accessible)
or invocation of the SUSPEND CLI command.
90 00
0E220064 The logical unit specified by the target WWLID field
has transitioned from the Logging state to the Merging
state due to a remote connection event (the target
controllers are inaccessible) or invocation of the
RESUME CLI command.
90 00
0E238F01 The logical unit specified by the Log Unit Number field
has failed.
90 8F
0E258F01 Write history logging encountered a write error on the
log unit.
90 8F
0E260064 There is no more space left at the end of the log unit
for write history logging.
90 00
0E278F01 Write history log merge encountered a read error on
the log unit.
90 8F
0E288F01 The log unit failed with a media format error. 90 8F
0E290064 The log unit was reset because the specified target
member was marked invalid. For instance, a site
failover detected or a full member copy has started.
90 00
0E2A8F01 The logical unit specified by the Log Unit Number field
is unknown or inoperative.
90 8F
0E2B0064 The log unit was reset due to loss of cached data for
the write history log. The specified target member was
marked for a full copy.
90 00
0E2C0064 A target member is being removed while write history
logging is active.
90 00
Table 53: Instance Codes and Repair Action Codes (Sheet 29 of 30)
Instance
Code
Description Template
Repair
Action
Code