HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Instance Codes
202 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03E0450A During device initialization, the device reported the
SCSI sense key, volume overflow. This condition
indicates that a buffered peripheral device has
reached the end-of-partition and data not written to
the medium may remain in the buffer. RECOVERED
BUFFER DATA commands may be issued to read the
unwritten data from the buffer.
41 45
03E1450A During device initialization, the device reported the
SCSI sense key, miscompare. This condition indicates
that the source data did not match the data read from
the medium.
41 45
03E2450A During device initialization, the device reported a
reserved SCSI sense key.
41 45
03E40F64 The EMU indicated that termination power is good on
all ports. In this instance, the Associated Target,
Associated ASC, and Associated ASCQ fields are
undefined.
41 0F
03E58002 The EMU detected bad termination power on the
indicated port. In this instance, the Associated Target,
Associated ASC, and Associated ASCQ fields are
undefined.
41 80
03EE0064 The EMU for the cabinet, indicated by the Associated
Port field, is available. In this instance, the associated
target, associated ASC, and the associated ASCQ are
undefined.
41 00
03EF8301 The EMU for the cabinet, indicated by the Associated
Port field, is unavailable. In this instance, the
associated target, associated ASC, and the associated
ASCQ are undefined.
41 83
Table 53: Instance Codes and Repair Action Codes (Sheet 22 of 30)
Instance
Code
Description Template
Repair
Action
Code