HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
Instance Codes
201HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03DA450A During device initialization, the device reported the
SCSI sense key, data project. This condition indicates
that a command that reads or writes the medium was
attempted on a block that is protected from this
operation. The read or write operation is not
performed.
41 45
03DB450A During device initialization, the device reported the
SCSI sense key, blank check. This condition indicates
that a write-once device encountered blank medium
or format-defined end-of-data indication while
reading or a write-once device encountered a
non-blank medium while writing.
41 45
03DC450A During device initialization, the device reported a
SCSI vendor-specific sense key. This sense key is
available for reporting vendor-specific conditions.
41 45
03DD450A During device initialization, the device reported the
SCSI sense key, copy aborted. This condition indicates
that a COPY, COMPARE, or COPY and VERIFY
command was aborted due to an error condition on
the source device, the destination device, or both.
41 45
03DE450A During device initialization, the device reported the
SCSI sense key, aborted command. This condition
indicates that the target aborted the command. The
initiator may be able to recover by trying the
command again.
41 45
03DF450A During device initialization, the device reported the
SCSI sense, key equal. This condition indicates that a
search data command has satisfied an equal
comparison.
41 45
Table 53: Instance Codes and Repair Action Codes (Sheet 21 of 30)
Instance
Code
Description Template
Repair
Action
Code