HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
200 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03D6450A During device initialization, the device reported the
SCSI sense key, medium error. This condition
indicates that the command stopped with a
nonrecovered error condition that was probably
caused by a flaw in the medium or an error in the
recorded data. This sense key may also be returned if
the target is unable to distinguish between a flaw in
the medium and a specific hardware failure
(HARDWARE ERROR sense key).
41 45
03D7450A During device initialization, the device reported the
SCSI sense key, hardware error. This condition
indicates that the target detected a nonrecoverable
hardware failure (for example, controller failure,
device failure, parity error, and so forth) while
performing the command or during a self-test.
41 45
03D8450A During device initialization, the device reported the
SCSI sense key, illegal request. This condition
indicates that there is an illegal parameter in the
command descriptor block or in the additional
parameters supplied as data for some commands
(FORMAT UNIT, SEARCH DATA, and so on). If the
target detects an invalid parameter in the command
descriptor block, the target stops the command
without altering the medium. If the target detects an
invalid parameter in the additional parameters
supplied as data, the target may alter the medium.
This sense key may also indicate that an invalid
identify message was received.
41 45
03D9450A During device initialization, the device reported the
SCSI sense key, unit attention. This condition indicates
that the removable medium was changed or the target
reset.
41 45
Table 53: Instance Codes and Repair Action Codes (Sheet 20 of 30)
Instance
Code
Description Template
Repair
Action
Code