HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
199HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03D14002 The identification of a device does not match the
configuration information. The actual device type is
unknown to the controller. In this instance, the
associated ASC, and associated ASCQ fields are
undefined.
41 40
03D24402 SCSI bus errors occurred during device operation.
The device type is unknown to the controller. In this
instance, the associated ASC and associated ASCQ
fields are undefined.
41 44
03D3450A During device initialization, the device reported the
SCSI sense key, no sense. This condition indicates that
there is no specific sense key information to be
reported for the designated logical unit. This would be
the case for a successful command or a command that
received check condition or command terminated
status because one of the FM, EOM, or ILI bits is set to
one in the sense data flags field.
41 45
03D4450A During device initialization, the device reported the
SCSI sense key, recovered error. This condition
indicates that the last command completed
successfully with some recovery action performed by
the target.
41 45
03D5450A During device initialization, the device reported the
SCSI sense key, not ready. This condition indicates
that the logical unit addressed cannot be accessed.
Operator intervention may be required to correct this
condition.
41 45
Table 53: Instance Codes and Repair Action Codes (Sheet 19 of 30)
Instance
Code
Description Template
Repair
Action
Code