HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
196 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03354002 During device initialization, a TEST UNIT READY
command or a READ CAPACITY command to the
device failed.
Passthrough 40
03364002 During device initialization, the device reported a
deferred error.
Passthrough 40
03374002 During device initialization, the maximum number of
errors for a data transfer operation was exceeded.
Passthrough 40
03384002 The REQUEST SENSE command to the device failed. Passthrough 40
03394002 A command timeout occurred. Passthrough 40
033A4002 A disconnect timeout occurred. Passthrough 40
033B4002 An unexpected bus phase occurred. Passthrough 40
033C4002 The device unexpectedly disconnected from the SCSI
bus.
Passthrough 40
033D4002 Unexpected message. Passthrough 40
033E4002 Message reject received on a valid message. Passthrough 40
033F0101 No command control structures are available for the
passthrough device operation.
Passthrough 01
03402002 The device port SCSI chip reported a gross error. Passthrough 20
03410101 A miscellaneous SCSI port driver coding error
occurred.
Passthrough 01
03420101 A passthrough device-related internal error code was
reported and was not recognized by the fault
management software.
Passthrough 01
03434002 During device initialization, the device reported
unexpected Standard SCSI Sense Data.
Passthrough 40
03BE0701 The EMU for the cabinet, indicated by the Associated
Port field, powered down the cabinet because there
are fewer than four working power supplies present.
In this instance, the Associated Target, Associated
ASC, and Associated ASCQ fields are undefined.
41 07
Table 53: Instance Codes and Repair Action Codes (Sheet 16 of 30)
Instance
Code
Description Template
Repair
Action
Code