HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
194 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
03044402 SCSI bus errors during disk operation. In this instance,
the associated ASC and associated ASCQ fields are
undefined.
41 44
03052002 Device port SCSI chip reported gross error during disk
operation. In this instance, the associated ASC and
associated ASCQ fields are undefined.
41 20
03062002 Non-SCSI bus parity error during disk operation. In
this instance, the associated ASC and associated
ASCQ fields are undefined.
41 20
03070101 Source driver programming error encountered during
disk operation. In this instance, the associated ASC
and associated ASCQ fields are undefined.
41 01
03080101 Miscellaneous SCSI port driver coding error detected
during disk operation. In this instance, the associated
ASC and associated ASCQ fields are undefined.
41 01
03094002 An unrecoverable disk drive error was encountered
while performing work related to disk unit operations.
51 40
030C4002 A drive failed because a TEST UNIT READY
command or a READ CAPACITY command failed.
51 40
030D000A Drive was failed by a MODE SELECT command
received from the host.
51 00
030E4002 Drive failed due to a deferred error reported by drive. 51 40
030F4002 Unrecovered read or write error. 51 40
03104002 No response from one or more drives. 51 40
0311430A Nonvolatile memory and drive metadata indicate
conflicting drive configurations.
51 43
0312430A The synchronous transfer value differs between drives
in the same storageset.
51 43
03134002 Maximum number of errors for this data transfer
operation exceeded.
51 40
03144002 Drive reported recovered error without transferring all
data.
51 40
Table 53: Instance Codes and Repair Action Codes (Sheet 14 of 30)
Instance
Code
Description Template
Repair
Action
Code