HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
192 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02892301 The cache backup battery is near end of life. The
Memory Address field contains the starting physical
address of the Cache A0 memory.
12 23
028A2301 The cache backup battery covering the mirror cache is
near end-of-life. The Memory Address field contains
the starting physical address of the Cache B1
memory.
12 23
028B3801 Memory diagnostics performed during controller
initialization detected that the DIMM in location 1
failed on the cache module. The failed DIMM should
be replaced as soon as possible. Control structures
have been moved to secondary memory and are now
unprotected against additional memory failures. In
this instance, the Byte Count field is undefined.
14 38
028C3801 Memory diagnostics performed during controller
initialization detected that the DIMM in location 2
failed on the cache module. The failed DIMM should
be replaced as soon as possible. Control structures
have been moved to secondary memory and are now
unprotected against additional memory failures. In
this instance, the Byte Count field is undefined.
14 38
028D0064 The device, specified in the Device Locator field, was
removed from the spareset into the failedset. The new
nominal number of members for the spareset is
specified in the device sense data Information field.
51 00
028F8901
02908901
02918901
The host command failed because the remote copy set
went failsafe locked prior to command completion.
The remote copy set is specified by the remote copy
name field. The Information field of the device sense
data contains the block number of the first block in
error.
51 89
Table 53: Instance Codes and Repair Action Codes (Sheet 12 of 30)
Instance
Code
Description Template
Repair
Action
Code