HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
191HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
027B2201 The Cache B1 memory controller failed cache
diagnostics testing performed on the other cache
during a cache failover attempt. The Memory Address
field contains the starting physical address of the
Cache B1 memory.
14 22
027C2201 The Cache B0 and Cache B1 memory controllers
failed cache diagnostics testing performed on the
other cache during a cache failover attempt. The
Memory Address field contains the starting physical
address of the Cache B0 memory.
14 22
027D5B01 The mirrorset associated with the logical unit is
inoperative due to a disaster tolerance failsafe locked
condition.
51 5B
027F2301 The cache backup battery is bad. The battery did not
fully charge within the expected duration. The
Memory Address field contains the starting physical
address of the Cache A0 memory.
12 23
02825C64 The mirrorset associated with the logical unit has just
had a membership change such that disaster
tolerance failsafe error mode can now be enabled if
desired.
51 5C
02864002 The controller has set the specified unit data safety
write-protected due to an unrecoverable device failure
that prevents writing cached data.
51 40
02872301 The cache backup battery has exceeded the maximum
number of deep discharges allowed. Battery capacity
may be below specified values. The Memory Address
field contains the starting physical address of the
Cache A0 memory.
12 23
02882301 The cache backup battery covering the mirror cache
has exceeded the maximum number allowed for deep
discharges. Battery capacity may be below specified
values. The Memory Address field contains the
starting physical address of the Cache B1 memory.
12 23
Table 53: Instance Codes and Repair Action Codes (Sheet 11 of 30)
Instance
Code
Description Template
Repair
Action
Code