HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Instance Codes
179HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Instance Code format
The format of an Instance Code as displayed in Sense Data Responses is shown in
Table 51.
Note: The offset values enclosed in braces ( { } ) apply only to the Passthrough Device
Reset Event Sense Data Response format (see Table 37 on page 137). The nonbraced
offset values apply only to the logical device event sense data response formats shown
in the templates provided in the Event Reporting Templates” chapter that starts on
page 135.
Notification and recovery threshold
Located at byte offset {8}32 is the Notification and Recovery (NR) threshold
assigned to the event. This two-digit value is used during symptom-directed
diagnosis procedures to determine when to take NR action. For a description of
event NR threshold classifications, see Table 52.
Table 51: Instance Code Format
offset
bit
7 6 5 4 3 2 1 0
{8}32 NR threshold
{9}33 Repair action
{10}34 Event number
{11}35 Component ID
Table 52: Event Notification and Recovery (NR) Threshold Classifications
Threshold
Value
Classification Description
01 Immediate Indicates either a failure or potential failure of a component
critical to proper controller operation; immediate attention is
required.
02 Hard Indicates either a failure of a component that affects controller
performance or inability to access a device connected to the
controller.