HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

ASC, ASCQ, Repair Action, and Component Identifier Codes
171HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
51 The mirrorset is inoperative for one of the following reasons:
The last Normal member has malfunctioned. Perform repair actions 55 and 59.
The last Normal member is missing. Perform Repair Action 58.
The members have been moved around and the consistency checks show
mismatched members. Perform Repair Action 58.
52 The indicated storageset member was removed for one of the following reasons:
The member malfunctioned. Perform Repair Action 56.
By operator command. Perform Repair Action 57.
53 The storageset may be in a state that prevents adding a replacement member. Check
the state of the storageset and its associated unit and resolve the problems found before
adding the replacement member.
54 The device may be in a state that prevents adding the device as a replacement member
or may not be large enough for the storageset. Use another device for the ADD action
and perform Repair Action 57 for the device that failed to be added.
55 Perform the repair actions indicated in any and all event reports found for the devices
that are members of the storageset.
56 Perform the repair actions indicated in any and all event reports found for the member
device that was removed from the storageset. Then, perform Repair Action 57.
57 Delete the device from the failedset and redeploy, for example, by adding the device to
the spareset so the device becomes available to replace another failing device.
58 Install the physical devices that are members of the storageset in the proper port, target,
and LUN locations.
59 Delete the storageset, recreate the storageset with the appropriate ADD, INITIALIZE,
and ADD UNIT CLI commands, and then reload the storageset contents from backup
storage.
5A Restore the mirrorset data from backup storage.
5B The mirrorset is inoperative due to a disaster tolerance failsafe locked condition, as a
result of the loss of all local or remote Normal and Normalizing members while
ERROR_MODE=FAILSAFE was enabled. To clear the failsafe locked condition, enter
the CLI command:
SET unit-number ERROR_MODE=NORMAL
Table 49: Recommended Repair Action Codes (Sheet 5 of 8)
Code Description