HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)
ASC, ASCQ, Repair Action, and Component Identifier Codes
164 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
91 1A First defined sub-LUN not formatted, second sub-LUN is
illegal.
91 1B Non sub-LUN drive already owned by another LUN.
91 1C Sub-LUN drive already owned by a non sub-LUN.
91 1D Drive type differs from others in LUN.
91 1E Drive cannot be added to rank because rank is full.
91 1F Ranks have different number of disks defined.
91 20 Multiple drives on same channel within same rank.
91 21 Mirrored disks on same channel.
91 22 No parity disk defined.
91 23 No data disks defined.
91 24 Too many disks defined.
91 25 No space available to define LUN. Sub-LUN cannot be
defined.
92 00 Controller cannot clear busy status from drive.
93 00 Drive returned vendor-unique sense data.
94 00 Invalid request of a redundant controller.
A0 00 Last Failure Event report.
A0 01 Nonvolatile Parameter Memory Component Event report.
A0 02 Backup Battery Failure Event report.
A0 03 Subsystem Built-In Self-Test Failure Event report.
A0 04 Memory System Failure Event report.
A0 05 Failover Event report.
A0 07 RAID Membership Event report.
A0 08 Multiple-bus failover event.
A0 09 Multiple-bus failback event.
A0 0A Disaster tolerance failsafe error mode can now be
enabled.
A0 0B Connection table is full.
Table 48: ASC and ASCQ Code Descriptions (Sheet 3 of 5)
ASC
Code
ASCQ
Code
Description