HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Event Reporting Templates
149HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Subsystem Built-In Self-Test Failure Event Sense Data Response
template (Template 13)
The controller subsystem built-in self-test software component reports errors
detected during test execution through the Subsystem Built-In Self-Test Failure
Event Sense Data Response (see Table 43). Errors are signaled to all host systems
on all logical units.
ASC and ASCQ codes (byte offsets 12 and 13) are detailed in the “ASC,
ASCQ, Repair Action, and Component Identifier Codes” chapter that starts
on page 161.
Instance Codes (byte offsets 32–35) are detailed in theInstance Codes
chapter that starts on page 177.
Table 43: Template 13—Subsystem Built-In Self Test Failure Event Sense Data
Response Format
offset
bit
7 6 5 4 3 2 1 0
0Unused Error code
1Unused
2 Unused Sense key
3–6 Unused
7 Additional sense length
8–11 Unused
12 ASC
13 ASCQ
14 Unused
15–17 Unused
18–31 Reserved
32–35 Instance Code
36 Template
37 Template flags
38–53 Reserved
54–69 Controller board serial number
70–73 Controller software revision level
74 Reserved or patch version (TM2)
75 Reserved
76 LUN status