SAN Switch 2/8 V3.1.x - Installation Guide
Installing the SAN Switch 2/8
53SAN Switch 2/8 Version 3.1.x Installation Guide
5. For the SAN Switch 2/8, assemble the two inner rails (one on each side) to the
switch and plenum using fourteen #8-32 x 3/16-inch Phillips pan-head screws
as shown in Figure 20.
Caution: Do not use any other screws other than the fourteen that are
provided. Use of any longer lengths can cause damage to internal
components
Note: Verify that the plenum (part number A7346-00001) is preinstalled on the SAN
Switch 2/8 before proceeding. The plenum is required for the SAN Switch 2/8 rack
mount only, as it allows air to dissipate at the rear of the rack, preventing
overheating. If the plenum shipped as a separate item, refer to Installing the Switch in
the Optional HP System/e Rack, step 5, for complete plenum installation instructions.
Figure 20: Assembling the inner rails on a SAN Switch 2/8 with plenum