SAN Switch 2/8 - Release Notes
SNMP-based Management
18 SAN Switch 2/8 Version 3.1.x Release Notes
SNMP-based Management
Many SNMP Fibre Channel Management programs have the capability to log
SNMP trap information (error and status events) occurring on the switch into the
Windows NT application Event log. To enable this capability, parameters must be
set on the switch.
Note: These parameters can be set either through Web Tools by selecting the admin.
button and clicking on the SNMP Admin tab, or by using the Telnet interface along with
the agtcfgSet Telnet command.
The switch will send one copy of a trap message to each IP address that is listed in
the communities. If you enter the same IP address into more than one of the
communities, you will get multiple copies of the same trap message.
■ swEventTrapLevel: (0..5)—must be set for a severity level from 0 to 5
— 0 – none
— 1 – critical
— 2 – error
—3 – warning
— 4 – informational
—5 – debug
■ authTrapsEnabled: (true, t, false, f)—must be set to true or t to enable
sending of traps
Note: This parameter is set to
true
or
t
by default.