MIB Reference Manual (Version 3.0)
MIB Reference Manual Version 3.0 4-87
FCSwitch MIB Object Types
4
swSensorScn (Obsoleted by swFabricWatchTrap)
Enterprise sw
Variables swSensorStatus, swSensorIndex, swSensorType, swSensorValue, swSensorInfo
Description A 2 (swSensorScn) is generated whenever an environment sensor changes its operational state. For
instance, a fan stop working. The VarBind in the Trap Data Unit shall contain the corresponding
instance of the sensor status, sensor index, sensor type, sensor value (reading) and sensor
information. Note that the sensor information contains the type of sensor and its number in textual
format.
swFCPortScn
Enterprise sw
Variables swFCPortOpStatus, swFCPortIndex
Description A 3 (swFCPortScn) is generated whenever an FC_Port changes its operational state. For instance,
the FC_Port goes from on-line to offline. The VarBind in the Trap Data Unit shall contain the
corresponding instance of the FC_Port's operational status and index.
#TYPE A sensor (temperature, fan, or other) changed its operational state.
#SUMMARY %s: is currently in state %d
#ARGUMENTS 4, 0
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational
#TYPE A Fibre Channel Port changed its operational state.
#SUMMARY Port Index %d changed state to %d
#ARGUMENTS 1, 0
#SEVERITY Informational
#TIMEINDEX 1
#STATE Operational