swFwCustUnit [swFwClassAreaTable]
Syntax Display String of size 0 to 256
Access Read-write
Status Mandatory
Description A customizable unit string name, used to identify the unit of measure for a Fabric Watch classArea
combination. For example:
C = environment (class), temperature (area).
RPM = environment (class), fan (area).
swFwCustTimebase [swFwClassAreaTable]
Syntax SwFwTimebase
Access Read-write
Status Mandatory
Description A customizable polling period for the Fabric Watch classArea combination. For example:
swFwTbMin = port (class), link loss (area).
swFwTbNone = environment (class), temperature (area).
swFwCustLow [swFwClassAreaTable]
Syntax Integer
Access Read-write
Status Mandatory
Description A customizable low-threshold value for a Fabric Watch ClassArea combination.
swFwCustHigh [swFwClassAreaTable]