MIB Reference Manual (Version 3.0)

MIB Reference Manual Version 3.0 4-55
FCSwitch MIB Object Types
4
swFwClassAreaIndex [swFwClassAreaTable]
Syntax SwFwClassesAreas
Access Read-only
Status Mandatory
Description This index represents the Fabric Watch classArea combination.
swFwWriteThVals [swFwClassAreaTable]
Syntax SwFwWriteVals
Access Read-write
Status Mandatory
Description This applies or cancels the configuration value changes.
Note: For a read operation, the return value is always swFwCancelWrite.
The following are the custom configuration variables that can be modified.
swFwCustUnit
swFwCustTimebase
swFwCustLow
swFwCustHigh
swFwCustBufSize
Changes to these custom configuration variables can be saved by setting this variable to
swFwApplyWrite, and they can be removed by setting this variable to swFwCancelWrite.
swFwDefaultUnit [swFwClassAreaTable]
Syntax Display String of size 0 to 256
Access Read-only
Status Mandatory
Description A default unit string name, used to identify the unit of measure for a Fabric Watch classArea
combination. For example:
C = environment (class), temperature (area).
RPM = environment (class), fan (area).